Abstract

Radiation can have undesirable effects on the eye, including a gradual loss of vision. Unnecessary radiation can reach the eye lens during non-enhanced computed tomography (CT) scans of the brain. The International Commission on Radiological Protection states the threshold for acute and chronic eye lens exposure is 500mGy and the equivalent dose limit for the eye lens for public exposure is 15mSv per year. Therefore, we measured the direct radiation dose to the eye lens during head CT scans using NanoDots in 216 adults. The mean absorbed dose to both eyes was 33.62mGy (standard deviation ±12.442). The averages for the other variables were: tube current-time product: 260 mAs; dose-length product: 708mGycm and CT dose index: 35.5mGy. Our findings encourage further study of radiation exposure and modifications in CT imaging protocols.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.