Abstract

At CPMI, we built a prototype portable, modified electrostatic spherical sector analyzer (ESA) device incorporating a neutral detector; investigated its capabilities for measuring energetic neutrals; and report results in this paper. This detector at the IF will contain a quartz crystal microbalance (QCM), Si witness plate for ex situ analysis, a set of microchannel plates (MCPs) with corresponding ion-diverting apparatus, Faraday cup as well as triple Langmuir probe. These detectors will be capable of quantifying total particle flux, neutral particle flux, and charged particle flux. To verify the capabilities of the detector, CPMI constructed a mock collector optic, which was placed inside the experimental chamber attached to CPMI's XTS 13-35 EUV source. This mock-up simulates the reflection of debris created by discharge-produced plasma (DPP), although it will not be capable of reflecting the EUV light. Recent results on the neutral, charged particle flux, and the carbon and oxygen contamination on a Si witness plate out of the line of sight of the Z-pinch are reported in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.