Abstract

The nose radius of a cutting insert is known to affect the surface roughness and dimensional accuracy of the finished product. Thus, accurate measurement of tool nose radius is important in tool quality monitoring. In this paper we present a new approach in measuring nose radii of multiple cutting inserts from scanned images using image processing. Batch processing of inserts solves the problem of the conventional method of measuring tool nose one at a time. Comparison of the measurement accuracy with a profile projector and the high resolution variable focus 3-D metrology system (Alicona InfiniteFocus) shows that the developed method using scanned images yields only 2.0 % error and gives about 3.0% of error with the repeated scanning of nose radius on various locations. In contrary, the conventionally digital profile projector methods gives error of radii measurement of 10.0% and high uncertainty compared to the InfiniteFocus. The specification limits of nose radius suggested by ISO 3685 are ±10% of the nominal radius. Hence the proposed measurement method using scanned images of inserts provides a low-cost yet fast and accurate assessment of automated tool nose measurement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.