Abstract

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Cross-track Infrared Sounder (CrIS) is a Fourier Transform interferometer-based sensor used to measure earth radiance at high spectral resolution and low spatial resolution. Measured radiance data are analyzed by end users to provide pressure, temperature and moisture profiles of the atmosphere. The CrIS instrument contains Mercury-Cadmium-Telluride (MCT) photovoltaic (PV) detectors with spectral response in the SWIR, MWIR and LWIR ranges. The CrIS instrument requires large area detectors with state-of-the-art detector performance at temperatures attainable with passive cooling. In the case of the LWIR bands noise associated with the detectors limit the instrument performance. In this paper we describe a study of the noise characteristics of a sample of CrIS MCT PV detectors, emphasizing acquisition and validation of 1/f noise measurements for these devices. Interesting aspects of the 1/f noise dependence on bias-voltage and bias-current are noted. The results are analyzed further in a companion paper1 that emphasizes the relationship between leakage current mechanisms in the diodes and 1/f noise observed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.