Abstract

The mass attenuation coefficients of the fabricated Rhizophora spp. particleboards were measured by using the Compton scattering technique and Ludlum configurations. The mass attenuation coefficents of the particleboards were measured at scattered gamma energies of 137Cs between 337.72 and 564.09 keV and compared to the its theoretical values and the values of water by using XCOM calculation. The results showed that the measured mass attenuation coefficients of the fabricated Rhizophora spp. particleboards were in good agreement to its theoretical values and water (XCOM) within 3.8 and 5.9% discrepancies. The results showed the near attenuation properties of the fabricated Rhizophora spp. particleboards to water at scattered gamma energies and the suitability of the Ludlum configuration for the measurement of mass attenuation coefficients of materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.