Abstract
Unevenness of the resin liquid surface causes uneven thickness of photo-hardened layers, resulting in reduced precision in stereolithography. Conventional stereolithography machines are equipped with leveling devices to prevent unevenness of the liquid surface. There however exists no system to measure flatness of the liquid surface at present, making it difficult to ensure flatness at all times. This paper proposes a device and method to measure uneven liquid surface. Factors causing measurement errors were analyzed, actual uneven surface shapes were measured, and measuring accuracy was examined to verify feasibility to apply this method to stereolithography. The developed equipment was found to be capable of measuring unevenness up to 6 microns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.