Abstract

Here the variation of a liquid-film thickness at small Reynolds numbers is discussed. The film thickness measurement by laser interferometry corresponds to the liquid flowing on the inner surface of a small-bore glass tube. An adequate theoretical background for the techniques used in this experiment is discussed to demonstrate the capability of the experimental technique. An advantage of this method is that it shows the shape of the thin film on the inner surface of the vertical tube at a point in a horizontal cross section. The results obtained from this experiment show that the flow of liquid films on vertical surfaces is inherently unstable and three dimensional even at a Reynolds number smaller than 1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.