Abstract

The measurement of joint motion is common practice in many aspects of orthopaedic surgery. A number of techniques and instruments have been developed for this purpose. We describe a method of recording and measuring knee joint motion using digital imaging which demonstrated high inter-observer reliability (r > 0.948) and intra-observer repeatability (r > 0.906). This technique may offer some practical advantages over other methods of measuring joint motion.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call