As a part of the systematic survey of indoor radon in Bulgaria, the indoor radon concentration was measured in 296 kindergarten buildings of Sofia city during 3 months (February to April 2013) using the CR-39 nuclear tract detectors. In 256 buildings at least two frequently occupied rooms (mainly playrooms) were observed. Altogether, 922 measurements were performed. The frequency distribution was well described by the lognormal function. The measured radon concentrations range between 9 and 1415 Bq m(-3) with a geometric mean of 101 Bq m(-3) (2.08) and an arithmetic mean 132 Bq m(-3) with a standard deviation of 118 Bq m(-3). The radon concentrations obtained in this survey were compared with that in Sofia city dwellings obtained from a previous study. A detailed statistical analysis of the building factors was presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.