Abstract

This paper describes the internal resonance phenomenon of a large scale superconducting coil. The frequency dependence of electric impedance defined at the coil terminal and the voltage distribution of the layer winding were measured at the ITER CS model coil under the superconducting state in advance of the pulse operation test. As a result, large change of the impedance and unbalance of the layer voltage were observed. The AC circuit analysis was carried out in order to evaluate the measurement results and to calculate the voltage of layer insulator. It was concluded that the higher voltage, which may appear on the layer insulation, is about a half of the coil terminal voltage in high frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.