Abstract

The CCQM-K128 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes in measuring the heavy metals and organo-tin in leather matrix material or other similar organics content materials, and a pilot study CCQM-P163 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. This comparison includes two parts: part A is for heavy metals (eight elements include As, Cd, Pb, Co, Cu, Hg, Ni, Sb) in leather powder with concentrations levels (30 ~ 100) mg/kg, and part B is for organo-tin (tributyltin) in leather powder with the concentration range (150~600) nmol/g.There were 10 laboratories registered and 9 laboratories returned the results, and different measurement methods (ID-ICPMS, ICP-MS, ICP-OES) with the microwave digestion were used in Part A; There were 3 laboratories registered and returned the results, and ID-LC-ICPMS, ID-GC-ICPMS and LC-ICPMS were used in Part B. After several rounds results and technical discussion at CCQM IAWG meeting, the KCRV and which associated uncertainty for each component had been confirmed.The comparison is to ensure the comparable and traceable measurement results for heavy metals and organo-tin in leather products among the NMIs and other designated measurement bodies worldwide. The consequence is relatively successful overall, although some problem of mercury and antimony determination had been discussed and summarized in this report. All participants have shown their capabilities and gained experience through this comparison. The results of CCQM-K128 are expected to cover the measurement capability and support the relative CMC claiming in the leather materials and similar high organics content matrix industrial products.KEY WORDS FOR SEARCHLeather, metal, Organo-TinMain textTo reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.