Abstract
A periodic transient test technique based on the axial dispersion model is proposed for the determination of both heat transfer coefficients and axial dispersion coefficients in heat exchangers. The model uses a parameter called the axial dispersive Peclet number to account for the deviation of the flow pattern from ideal plug flow. It takes both axial dispersion in the fluid and axial heat conduction in the wall into account and is solved analytically by means of a complex Fourier transform. Experiments conducted on dented copper tubes show that axial dispersion has a significant effect on the dynamic temperature response of a heat exchanger.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.