Abstract

Abstract Geosynthetic clay liners (GCLs) are often selected as a part of the barrier layer for cover systems in solid waste landfills to prevent infiltration of rainfall and migration of biogas into the atmosphere. To address the ability of GCLs to mitigate gas flow through cover layers, this paper presents an apparatus and testing method to measure the gas permeability of non-saturated and strained GCLs in the laboratory. The test is performed following a transient gas flow regime, and the test results are interpreted using a simple analytical solution. A series of gas permeability tests was performed on a needle-punched GCL with a degree of saturation between 32 % and 47 %. The specimens were tested under a 20 kPa load and 1.3 % strain in the radial direction, whereas the gas flow was induced by a gas differential pressure of less than 4 kPa. The results show that both the apparatus and the testing method can provide a reliable, fast, and simple method to measure the gas permeability of GCLs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.