Abstract
The development of a micropyrolysis gas Chromatographie technique for the determination of free choline in plasma and erythrocytes is reported as a means to clinically assess choline status. A micropyrolyzer syringe unit was fabricated and the method was standardized through repeated trials with a single plasma specimen. The interassay coefficient of variance was 1.3% for the standardized trials on plasma and erythrocytes. Choline status was assessed in control women, mothers and premature infants at birth and up to 14 days of life. At birth, plasma choline levels in the infants (32.2 ± 5.5 μmol/l) were significantly higher than those in the mothers (12.9 ± 2.6 μmol/l) and the control women (16.9 ± 1.6 μmol/l). The infants' plasma choline concentrations had decreased significantly by 7 days of life and remained at the lower level at day 14, independent of the nutritional intervention administered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.