Abstract

ABSTRACT The Lang x-ray diffraction technique provides a simple non-destructive method for measuring flexure in single-crystal silicon wafers at different stages of integrated circuit fabrication. A molybdenum target provides Kα1 and Kα2 x-radiation which is diffracted from the set of {110} normal to the surface parallel {111}. The widths of the diffracting regions and their separation are simply related to the flexure, which may be expressed as a radius of curvature (p). This method is limited to wafers which do not diffract from the entire region irradiated, i.e. p 1590 in. for a substrate to 203 in. after several processing stages. Non-uniformity in individual wafers is much greater after the material has been through several processing stages.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.