Abstract
ABSTRACTFatigue crack growth rate data are required in order to carry out a numerical analysis of the fatigue performance of complex structural components. These data are obtained by measuring crack growth in standard fracture mechanics specimens. A new method for measuring fatigue crack growth in compact tension specimens has been developed. The technique is based on the measurement of the surface magnetic fields produced when passing a high‐frequency alternating current through the specimen. Fatigue crack growth data recorded using this method indicated an accuracy of ±0.02 mm when compared with optical measurements. The technique is suitable for computer‐controlled operation and could easily be applied to other standard specimen geometries.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Fatigue & Fracture of Engineering Materials & Structures
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.