Abstract
The electrostatic charge generated on drug/excipient particles during the formulation, manufacture, and use of pharmaceutical dry powder inhaler (DPI) devices may significantly affect the performance of such devices. An experimental investigation has been undertaken of charge accumulation and decay on compacts of selected powders (lactose and salbutamol sulfate) and a device material (polyvinyl chloride, PVC) used during the formulation, manufacture, and use of DPIs. Significant differences in charge acquisition and decay for the three materials have been demonstrated after charging using a corona electrode. PVC acquired the highest charge, which decayed rapidly in 30 min toward the value prior to exposure to corona. Lactose and salbutamol acquired similar charge values, which decayed to zero after 30 min for lactose, whereas salbutamol retained a significant charge after 120 min. The significant differences in charging propensity among drug, excipient, and device materials may have relevance in DPI formulation, manufacture, and use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.