Abstract

In order to analyze the problems of the liquid hydrogen pump, the pressure of liquid hydrogen was measured at extremely low temperatures. At the temperature of 20 K, measurements of static pressure calibration, temperature sensitivity and dynamic pressure were carried out, using piezoelectric sensors, for indicator analysis of the engine combustion chamber. It was determined that piezoelectric sensors have the capability of measuring dynamic pressure under these extreme conditions.