Abstract

In this paper, a device with swinging plate electrodes has been proposed to measure contact electrification of a liquid sample. The proposed structure is composed of two parallel metallic plates immersed in a dielectric liquid. One of the plates is swinging with a constant frequency in a range from 0.4 to 4 Hz. The paper investigates the dependence in time and frequency of electrode velocity and streaming electrification. The measured current occurs for a very low intermittent velocity of less than 10 mm/s. In this range, the electrification current is around 50 pA. For higher velocities of up to 150 mm/s, the current is at the level of 1200 pA. The time–frequency characteristic using short-time Fourier transform shows no temporal changes in the frequency spectrum. The dependence of electrification on shuttle speed was calculated and it can be approximated with a second order polynomial model with the determination coefficient higher than 0.9. The advantage of the sensor is the ability to measure electrification phenomena without the necessity of having rotating electrodes or having a large volume of flowing liquids.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.