Abstract
This paper proposes a method to measure the dense-phase bed height by edge-detection of Charge Coupled Device based on flame image processing technique in Circulated Fluidized Bed (CFB) boiler. The detection system was installed in a 480t/h CFB boiler, image processing model has been built,and in-situ experiment was carried out. Real-time bed height is reliable and meets the bed pressure drop exactly in furnace. The monitoring equipment, the flame image processing theory of recognition algorithm, and the choice of the threshold value of gray, are introduced in the paper.This image processing technique can provide CFB boiler with the safe, economic and clean operation in practical industry application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.