Abstract

Joint sample tests have been carried out as a qualification test for ITER Toroidal Field (TF) coils. The joint sample comprises two short TF conductors that have “twin-box” joint terminals at both ends. The lower joint is a testing part that is a full size joint of the TF coils. Hall probes are attached on the lower joint box at around the center of the external field coil of the test facility. The magnetic field induced by shielding currents in the joint can be estimated from the difference between the measured magnetic field strength and the magnetic field generated by the external field coil. The magnetic field by the shielding currents during shut-off of the external field coil from -1.0 T is evaluated for six samples. The decay time constants of the shielding currents are gradually elongated with decrease of the shielding currents in all the samples. In comparison with simulation results, it is considered that the main shielding current flows in superconducting cables in the two conductors with crossing the jointed plane and that the joint resistance is decreased at low total current.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call