Abstract
The value of monitoring titers of cryptococcal antigen in serum and cerebrospinal fluid (CSF) during therapy for AIDS-associated cryptococcal meningitis was evaluated. Baseline and final titers of antigen in serum and CSF from participants in two studies of such therapy were categorized as increased (a rise of at least two dilutions), unchanged, or decreased (a fall of at least two dilutions). There was no correlation between outcome and changes in serum titers of cryptococcal antigen during treatment for acute meningitis or during suppressive therapy. During therapy for acute infection, an unchanged or increased titer of antigen in CSF was correlated with clinical and microbiological failure to respond to treatment; the correlation was especially strong among patients whose baseline titer of antigen was > or = 1:8 (P = .01). A rise in CSF antigen titer during suppressive therapy was associated with relapse of cryptococcal meningitis (P < .001). We conclude that serial monitoring of cryptococcal antigen, as conducted in these studies, has a limited role in the management of AIDS patients with cryptococcal meningitis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.