Abstract

Crosshair shift with changing magnification of VIS camera is investigated in this article. The shift is a real problem that can significantly worsen fire-control system performance. The main condition of this measurement is ability to perform it on mounted devices in real fire-control system in field condition, it means that the measurement is adjusted to be done with accessible equipment. To measure this shift it is important to design target image which enables the shift measurement. Inaccuracy of this measurement is also discussed. The theoretical solution of the problem is demonstrated on experimental measurement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.