Abstract

AbstractWe report on a novel method for measuring the bond strength of metal/ceramic interfaces. Test specimens are created by vapor depositing a metal film on a ceramic substrate. The specimen is impacted with a thin metal flyer sending a short planar shock pulse into the ceramic. If the shape and amplitude of the wave is properly controlled the interface will spontaneously debond creating new free surfaces.Measurements indicate the debonding process occurs in less than 1.0 ns, which we believe is too short for crack propagation along existing flaws. Therefore, we conclude that simultanious breaking of atomic bonds rather than propagation and coalescence of cracks is the means by which the film and substrate are separated. The free surface velocity of the metal overlayer is monitored during spall by laser interferometry. The data constitute a direct measurement of the bond strength. The measured bond strengths are reproducible and do not show a dependence on shock amplitude for identically prepared specimens.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.