Abstract

The spectral shape of noise emissions from a 35-GHz gyroklystron input cavity is used to directly measure the cavity resonant frequency and quality factor under beam-loaded conditions. The quality factors obtained with this technique at a number of magnetic fields are found to be consistent with quality factors obtained from reflection coefficient measurements made at the identical operating points. The measured variation in quality factor is used to identify various regimes of operation based on input cavity coupling. Comparisons between the measurements and simulations are in good agreement in resonant frequency, but moderate discrepancies in quality factor exist.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.