Abstract

To measure and compare the anterior loop length (ALL) for the mandibular canal and the mandibular incisive canal diameter (ICD) at its origin in cadavers using anatomy and cone beam computed tomography (CBCT) to safely install endosseous implants in the most distal area of the interforaminal region. The ALL and ICD were measured using CBCT in 4 cadavers, and using anatomy in 71 cadavers. The ranges and mean +/- SD for the anatomic measurements were: ALL, 0.0 to 9.0 mm and 1.9 +/- 1.7 mm; ICD, 1.0 to 6.6 mm and 2.8 +/- 1.0 mm. The average discrepancies between CBCT and anatomic measurements were 0.06 mm or less for both the ALL and the ICD, which were less than the resolution of CBCT. Because large variations in measurements were observed, both for ALL and ICD, no fixed distance mesially from the mental foramen should be considered safe. The ALL and the ICD can be estimated from the CBCT measurement. The preoperative CBCT measurement yields important information for each case.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.