Abstract

Introduction: To prove the suitability of multiplex analysis for measurement of changes of cytokines and angiogenetic factors in intraocular fluid of patients with proliferative diabetic retinopathy (PDR) and to determine its clinical applicability for future routine use in ocular medicine. Patient cohort: Patients with proliferative diabetic retinopathy. Control group patients before cataract surgery without any ocular pathology Methods: Intraocular fluid samples were aspirated from anterior chamber of patients with PDR. Concentrations of IL8, VEGF, EGF, IL 6, IP10, MCP1, PDGF, Rantes, BDNF, CNTF TGFb1 and IL 10 were measured simultaneously in intraocular fluid using multiplex panel kits from Millipore comp. (USA) and Luminex 100 instrument (Luminex corp., USA). Levels of biomarkers were compared between groups by Wilcoxon test. Results: Multiplex analysis is a suitable method for angiogenesis promotors measurement, because concentrations were generally measurable through the use of multiplex analysis. Complete results will be presented but a most important observation we confirmed were significantly increased concentrations of VEGF in PDR patients in comparison to control group. Conclusion: Multiplex analysis enables an easy simultaneous measurement of multiple markers in a very small sample volume and so enables the use of biomarker analyses in intraocular fluid in a future as a standard method. Prospective: To confirm the right choice of analytes and the system of results interpretation for multiplex panel in larger patient cohorts and to evaluate the possibilities of use in diagnosis patient monitoring in ocular medicine. Measurement of Angiogenesis Promotors and Cytokines Concentrations in Intraocular Fluid of Patients with Proliferative Diabetic Retinopathy Jindra Vrzalova*, Kozova Marketa, Rusnak Stepan, Ricarova Renata, Topolcan Ondrej Immunoanalytic Laboratory and Eye Department of University Hospital and Medical Faculty in Pilsen,Plzen,Czech Republic doi:10.4172/2155-9929.1000014

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.