Abstract

A centrosymmetric square grating was developed in this paper. Moiré fringes produced by the two centrosymmetric square gratings are highly sensitive with the misalignments and misaligned directions. The distance between the mismatched moiré fringes are expected to be measured directly by an infrared (IR) microscope without requiring any external reference. Using two pair of the moiré square gratings, misalignments of bonded wafers are proposed to be measured in the X–Y–θ axis simultaneously on wafer scale. The measurement accuracy of 0.5 µm in the X–Y axis and 3×10-4 deg in the θ-axis is presented as an example, which is sufficient for the alignment accuracy of currently available wafer bonding. Moreover, the measurement accuracy by this moiré method can be improved to nanometer level if the fabrication errors and IR microscope resolution are allowed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.