Abstract
The behaviour of common alkyl-2-cyanoacrylates in air has been investigated. Increasing humidity was found to increase the rate of polymerisation, although polymerisation is not instantaneous, even at high humidities. Sampling methods for these compounds have been studied and we are able to recommend a pumped Tenax sampling tube, although certain sampling limitations apply, notably that specified flow rates must be applied and that a maximum sampling time of four hours is recommended. Significant errors can occur if sampling is performed outside the range of conditions specified. Upon completion of sampling the tube is desorbed into 0.2% phosphoric acid in acetonitrile. The resulting solution is analysed by HPLC. Crown Copyright © 1998 Published by Elsevier Science Ltd on behalf of British Occupational Hygiene Society
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.