Abstract

The performances of two Laser Doppler Velocimetry (LDV) systems adapted for measuring the acoustic particle velocities are assessed in enclosed sound field. This assessment is performed by comparing the acoustic velocities measured by means of LDV to reference acoustic velocities estimated from sound pressure measurements. The two LDV systems are based on a single optical bench which delivers an optical signal called Doppler signal. The Doppler signal, which is frequency modulated, is analyzed by means of two signal processing systems, the BSA (Burst Spectrum Analyser from Dantec) on the one hand, and a system specifically developed for the estimation of the acoustic velocity on the other hand. Once the experimental setup has been optimized for minimizing the errors made on the reference velocities, the assessment is performed and shows that both systems can measure the acoustic velocity in enclosed field in two the frequency ranges [0–4 kHz] and [0–2 kHz] respectively for acoustic velocity amplitudes of 10 mm/s and 1 mm/s.