Abstract
The present procedure for analysing 90Sr combines the use of a non radioactive carrier with high pressure ion chromatography separation, conductivity detection of the carrier and optimized external counting by liquid scintillation. This improvement with respect to traditional methods led to a more rapid and efficient purification stage. The present work proves that activities of 90Sr as low as 3 Bq/L can be measured in highly contaminated pressurized water reactor primary coolant matrix without any observed radiochemical interference. The approach shows promise for the analysis of other emitters of low energy radiation, or isotopes subject to high background or matrix effects in a PWR primary coolant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.