Abstract

Surface quality problems in continuous cast steel are greatly affected by heat transfer across the interfacial layers in the gap between the solidifying steel shell and the mold. An experimental apparatus has been constructed to measure temperatures in the steel, mold flux layers, and copper under conditions approximating those in continuous casting. The flux solidified in multiple layers similar to those observed from continuous casting molds and contained many gas bubbles. Flux conductivities average about 1.0 W/m·K and appear to evolve with time. Contact resistances at both interfaces are significant and average about 0.0015 m 2·K/W. Flux crystallization appears to be the only significant effect of flux composition. The one glassy flux tested had much greater thermal conductivities, presumably due to radiation transport. Temperature and gap thickness had a negligible effect on the properties. These properties depend on the model used to extract them. They are being implemented into a mathematical model to simulate heat transfer in the mold, interface, and solidifying shell of a continuous slab-casting machine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.