Abstract
Magnetostriction of nonoriented electrical steel was measured under rotating flux magnetization conditions which occur in AC electrical machine stator cores, and compared with the magnetostriction calculated from a model based on a mechanical elasticity analogy. Shear magnetostriction and magnetostriction perpendicular to the magnetization direction are accounted for in the model which leads to an accurate representation of magnetostriction throughout the electrical steel lamination plane. This has the potential for improving the accuracy of stator core deformation and vibration calculations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.