Abstract
The coherent Laslett tune shifts are studied by measuring the dependence on circulating intensity of the coherent betatron oscillation frequency at 8 GeV. The power supply control was modified to adjust the quadrupole currents so as to cancel beam induced tune changes. The article reports on running experience with this modification as well as on the data, its acquisition and reconciliation with the Laslett formulas. 3 refs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.