Abstract

Equivalent impedances (EQIM) of three-stage synchronous induction coil launcher (SICL) under the different conditions, such as the EQIM before three-stage driving coils are assembled, the EQIM with armature and without armature after three-stage driving coils are assembled, are measured by means of digital electric bridge of UC2856A. Measurement results under the different conditions are compared and analyzed. The change laws of equivalent inductance (EQIN) and equivalent resistance (EQRE) of each stage versus the armature’s location are provided when the armature moves along the axial line of the three-stage SICL. Measurement results are in accordance with the theoretical analysis results of EQIN and EQRE of each stage. These have important significances for the prediction of each stage driving current’s wave and the determination of the initial value of each stage driving current’s change ratio at energized time in the solution process of the firing control model.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.