Abstract

The 6 circular grating eccentricity errors model attempts to improve the measurement accuracy of an articulated arm coordinate measuring machine (AACMM) without increasing the corresponding hardware cost. We analyzed the AACMM’s circular grating eccentricity and obtained the 6 joints’ circular grating eccentricity error model parameters by conducting circular grating eccentricity error experiments. We completed the calibration operations for the measurement models by using home-made standard bar components. Our results show that the measurement errors from the AACMM’s measurement model without and with circular grating eccentricity errors are 0.0834 mm and 0.0462 mm, respectively. Significantly, we determined that measurement accuracy increased by about 44.6% when the circular grating eccentricity errors were corrected. This study is significant because it promotes wider applications of AACMMs both in theory and in practice.