Abstract

An experimental set-up has been described, allowing for reliable relative intensity noise (RIN) measurements for a wide feedback range. It could be verified experimentally for DFB lasers that the transition to the coherence collapic regime occurs at significantly larger feedback levels, if the laser is operated at larger optical powers. Furthermore, it has been noted that a large coupling strength κL in DFB lasers is beneficial for improved stability against optical feedback.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.