Abstract
Studies were conducted in 14 mongrel dogs to compare resistivities in normal muscle with those from muscle subjected to electrical burns. One-ampere, 60-Hz currents were passed between the hind limbs of the dogs producing injury in three measurement regions of the gracilis muscle. Histology, heart rate, body temperature, arterial and pulmonary artery pressure, cardiac output, hematocrit, leukocyte counts, fibrinogen levels, and platelet levels were determined. Muscle resistivity associated with severe tissue necrosis was 70% lower than control values. Resistivity in tissue showing edema and minimal necrosis decreased 20 to 40% from control values. Muscle showing only edema had a 10 to 30% decrease in resistivity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.