Abstract
To examine the kinetic characteristics of platelet (PLT) destruction and thrombopoiesis by using mean platelet volume (MPV) and platelet distribution width (PDW). Using the ADVIA2120i instrument, we measured PLT counts, MPV, and PDW in 153 healthy individuals, 35 patients with immune thrombocytopenic purpura (ITP), and 48 patients with essential thrombocytopenia (ET). In the ITP group, the MPV and PDW were higher than those values in healthy individuals. In the ET group, the MPV was lower than in the ITP group and in healthy individuals, and the PDW was lower than in the ITP group. When the ITP group was subdivided (PLT counts <45 × 103/µL vs ≥ 45 × 103/µL), the MPV and PDW tended to be higher in patients with PLT counts less than 45 × 103 per µL. When patients with ET were subdivided (PLT counts <770 × 103/µL vs ≥770 × 103/µL), the MPV and PDW were lower in patients with PLT count of 770 or greater × 103 per µL. In ITP, the overall PLT composition varies, and PLT sequestration is nondiscriminatory. In ET, PLTs quickly shrink and remain small, resulting in a high proportion of small-sized PLTs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.