Abstract

The aim of our study was twofold: 1) to establish a mathematical link between mean aortic pressure (MAP) and systolic (SAP) and diastolic aortic pressures (DAP) by testing the hypothesis that either the geometric mean or the harmonic mean of SAP and DAP were reliable MAP estimates; and 2) to critically evaluate three empirical formulas recently proposed to estimate MAP. High-fidelity pressures were recorded at rest at the aortic root level in controls (n = 31) and in subjects with various forms of cardiovascular diseases (n = 108). The time-averaged MAP and the pulse pressure (PP = SAP - DAP) were calculated. The MAP ranged from 66 to 160 mmHg [mean = 107.9 mmHg (SD 18.2)]. The geometric mean, i.e., the square root of the product of SAP and DAP, furnished a reliable estimate of MAP [mean bias = 0.3 mmHg (SD 2.7)]. The harmonic mean was inaccurate. The following MAP formulas were also tested: DAP + 0.412 PP (Meaney E, Alva F, Meaney A, Alva J, and Webel R. Heart 84: 64, 2000), DAP + 0.33 PP + 5 mmHg [Chemla D, Hébert JL, Aptecar E, Mazoit JX, Zamani K, Frank R, Fontaine G, Nitenberg A, and Lecarpentier Y. Clin Sci (Lond) 103: 7-13, 2002], and DAP + [0.33 + (heart rate x 0.0012)] PP (Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. Catheter Cardiovasc Interv 63: 419-425, 2004). They all provided accurate and precise estimates of MAP [mean bias = -0.2 (SD 2.9), -0.3 (SD 2.7), and 0.1 mmHg (SD 2.9), respectively]. The implications of the geometric mean pressure strictly pertained to the central (not peripheral) level. It was demonstrated that the fractional systolic (SAP/MAP) and diastolic (DAP/MAP) pressures were reciprocal estimates of aortic pulsatility and that the SAP times DAP product matched the total peripheral resistance times cardiac power product. In conclusion, although the previously described thumb-rules applied, the "geometric MAP" appears more valuable as it established a simple mathematical link between the steady and pulsatile component of aortic pressure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.