Abstract
Mesoporous bioactive glass (MBG) and composite microspheres with MBG particles embedded in biodegradable poly(D,L-lactide-co-glycolide) (PLGA) matrix have been prepared and used to load gentamicin (GS). The in vitro drug release experiments from both MBG and composite microspheres were conducted in distilled water and phosphate buffered saline (PBS) solution at 37 degrees C for more than 30 days. In both water and PBS, GS release from the MBG was very fast with about 60 wt % of the loaded drug released in the first 24 h, and more than 80 wt % released in two days. MBG/PLGA composite microspheres showed an initial release of about 33 wt % in the first day, and 48 wt % in 2 days, and a subsequent sustained release lasting for more than 4 weeks in PBS. MBG/PLGA composite microspheres may be used as an alternative drug release system, especially as a bone void filler for bone repair due to their combined advantages of sustained release of antibiotics and apatite-forming ability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Biomedical Materials Research Part B: Applied Biomaterials
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.