Abstract
Some of the values reported in the legend of Figure 1 were incorrect as published. The authors regret the error and thank Dr. Daniel G.Q. Chong, PhD, and Dr. Lauren J. Bains, PhD, both from the Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern Switzerland, for identifying the errors. The legend for Figure 1 appeared as follows: Figure 1. Simulated normalized logarithmic diffusion signal intensity (log(S(b))/S(0)) as a function of b-value based on values reported by Riches et al (13). The estimated values of ADC400 and ADC700 were obtained from the standard monoexponential model and the estimated values of D and f were obtained from the revised monoexponential model. A: For benign PZ, the simulated biexponential signal was generated using the following reported parameters (13): D = 1.45 × 10−3 mm2/s, f = 0.20, and D* = 21.20 × 10−3 mm2/s. Estimated ADC values were: ADC400 = 2.00 × 10−3 mm2/s, ADC700 = 1.80 × 10−3 mm2/s. Estimated values for the revised monoexponential were: D = 1.45 × 10−3 mm2/s, f = 0.20. B: For tumor the simulated biexponential signal was generated using the following reported parameters (13): D = 1.10 × 10−3 mm2/s, f = 0.15, and D* = 25.20 × 10−3 mm2/s. Estimated ADC values were: ADC400 = 1.50 × 10−3 mm2/s, ADC700 = 1.30 × 10−3 mm2/s. Estimated values for the revised monoexponential were: D = 1.10 × 10−3 mm2/s, f = 0.15. It should have appeared as follows: Figure 1. Simulated normalized logarithmic diffusion signal intensity (log(S(b))/S(0)) as a function of b-value based on values reported by Riches et al (13). The estimated values of ADC400 and ADC700 were obtained from the standard monoexponential model and the estimated values of D and f were obtained from the revised monoexponential model. A: For benign PZ, the simulated biexponential signal was generated using the following reported parameters (13): D = 1.45 × 10−3 mm2/s, f = 0.20, and D* = 21.20 × 10−3 mm2/s. Estimated ADC values were: ADC400 = 2.01 × 10−3 mm2/s, ADC700 = 1.77 × 10−3 mm2/s. Estimated values for the revised monoexponential were: D = 1.45 × 10−3 mm2/s, f = 0.22. B: For tumor the simulated biexponential signal was generated using the following reported parameters (13): D = 1.10 × 10−3 mm2/s, f = 0.15, and D* = 25.20 × 10−3 mm2/s. Estimated ADC values were: ADC400 = 1.51 × 10−3 mm2/s, ADC700 = 1.33 × 10−3 mm2/s. Estimated values for the revised monoexponential were: D = 1.10 × 10−3 mm2/s, f = 0.16.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.