Abstract

A thermodynamic model was developed to analyze the performance of cogeneration plant based on irreversible recuperative Brayton cycle. A parameter, dimensionless total useful energy rate (DTUER), was used as the criterion for performance optimization of cogeneration plant. The effects of cycle parameters, internal irreversibilities, and recuperator efficiency on maximum DTUER and on the efficiency at maximum DTUER were numerically investigated. The relation between DTUER and cogeneration efficiency was also analyzed. The results show that there exists an optimal compressor pressure ratio which maximizes the DTUER. It is also found that there exists an optimal power-to-heat ratio which results in a dual-maximum DTUER.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.