Abstract
This paper proposes a novel method of using maximum torque per ampere (MTPA) control for direct torque control (DTC) of a permanent-magnet synchronous motor (PMSM) in the stator flux linkage synchronous (M-T) frame. The stator flux vector estimation of DTC enables use of the M-T frame. Consideration of the magnetic saturation and cross-coupling effects in PMSMs requires significant complexity in most of the mathematical models using the rotor synchronous ( $d-q$ ) frame. In the M-T frame, the mathematical model for MTPA control requires only three parameters that can be determined from only three measured points. The validity of the proposed method is confirmed by experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.