Abstract
In this study an algorithm was developed for calculating maximum detectable distance (MDD) for mobile gamma-ray detection of lost sources in-situ for some common mobile spectrometer systems and gamma sources (137Cs and 60Co). The MDD is a function of detector efficiency, vehicle speed, acquisition time interval, radiation background level and accepted frequency of false alarms. To test its accuracy in predicting the MDD experiments were conducted in-situ. Results indicate agreement with experimental mobile detection distance measurements for 60Co and 137Cs point sources. Both the algorithm and the field test show that at a vehicle speed of 50 km/h, the optimal acquisition time intervals range between 3 and 10 s when searching for unshielded sources with activities of 137Cs and 60Co in the order of 100 MBq. Longer acquisition time intervals (20–30 s) are better to detect higher activity sources at the same speed. However, at higher speeds, shorter time intervals should be selected to increase the MDD. The developed algorithm can help select the optimal combination of detectors, vehicle speed, and instrument settings when using mobile searching in the event of loss of gamma-ray sources.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.