Abstract

This paper proposes and verifies a specific absorption rate (SAR) measurement procedure for multi-antenna transmitters that requires measurement of two-dimensional electric field distributions for the number of antennas and calculation in order to obtain the three-dimensional SAR distributions for arbitrary weighting coefficients of the antennas prior to determining the average SAR. The proposed procedure is verified based on Finite-Difference Time-Domain (FDTD) calculation and measurement using electro-optic (EO) probes. For two reference dipoles, the differences in the 10g SAR obtained based on the proposed procedure compared numerically and experimentally to that based on the original calculated three-dimensional SAR distribution are at most 4.8% and 3.6%, respectively, at 1950MHz. At 3500MHz, this difference is at most 5.2% in the numerical verification.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.