Abstract

ABSTRACTThe French ministry responsible for transport has commissioned a study aimed at providing data to determine the maximum gap size between vehicle and platform for guided transport vehicles, which would become a legal requirement. Specific experimental conditions were created, with a physical mock-up simulating a tramway and a platform and providing several gap configurations (between 20 and 50 mm for the horizontal gap and between 20 and 75 mm for the vertical step), and an experimental design based on the negotiation of gaps by wheelchairs users (mainly manual or electric powered). The experiment was conducted with 46 participants with different functional abilities. Data were collected on performance and gap negotiation time. The results of this study indicate that despite the failures observed for the 50 × 50 mm gap size during the experiment, most wheelchair users who took part in the test have successfully negotiated this gap.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.