Abstract

This study uses matrix optics to develop a model to predict depth of field in eyes that may have astigmatic elements and apertures that may be elliptical in general. Depth of field is modelled as the visual acuity (VA) as a function of working distance and is illustrated graphically for model eyes that have artificial intraocular pinhole apertures. A small amount of residual myopia is an advantage to increasing the depth of field at near without interfering with distance-vision. A small amount of residual astigmatism is not an advantage to increasing depth of field, without compromising VA at all distances.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call