Abstract
This paper aims to construct a material developing approach matching to an injection moulding rejuvenation technique for cable insulation failure. The work starts from a chemical composition testing to the cable original insulation material. The applied composition should be determined by considerations of property requirements, including insulation, mechanical behaviour and environmental adaptability. In addition, a stable and standard manufacture technology should be groped to assure having a stable repair quality. Finally, proper material should be verified by testing for meeting normal the cable insulation requirements. By the above approach, typical material development is performed and the results by a code-based insulation property testing reveal the present approach has successfully been applied to develop a proper material matching to injection moulding rejuvenation technique for cable insulation failure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.