Abstract

The purpose of the present study was to investigate in vitro the biomechanical material and knot properties and histomorphometrical knot properties of 3-0 braided polyester suture (Ticron) and bioabsorbable poly-L/D-lactide (PLDLA) 96/4 suture. In Ticron five throws are needed to form a secure knot, and the 1 = 1 = 1 = 1 = 1 and the 2 = 1 = 1 = 1 configurations are recommended. For PLDLA several granny and square knots formed a secure knot, but the 1 = 1 and 1 = 1 = 1 knots were the best. These PLDLA knots had lower yield force and strain at yield point, but higher stiffness than the recommended Ticron knots. The ultimate force values did not differ, but PLDLA knots had significantly higher strain at ultimate point. In the histomorphometrical analysis of the recommended knots, the PLDLA knots had a significantly smaller knot surface area than the Ticron knots. According to these results, PLDLA suture proved to be suitable for flexor tendon repair.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.